- Averages up to 10 RTD Sensors
- Automatic Cold Junction Compensation
- NEMA 4X, IP65 Front
- Universal 85-265 VAC or 12/24 VDC Input Power
- Large Dual-Line 6-Character Display, 0.60" & 0.46"
- Programmable Displays & Function Keys
- Sunlight Readable Display
- 2 or 4 Relays + Isolated 4-20 mA Output Options
- External 4-Relay & Digital I/O Expansion Modules
- RS-232, RS-422/485 Serial Communication Options
- Modbus® RTU Protocol Standard
1. Panel cutout required: 1.772 in x 3.622 in (45mm x 92mm)
2. Panel thickness: 0.040 - 0.250 in (1.0mm - 6.4mm)
3. Mounting brackets lock in place for easy mounting
4. Clearance: Allow 6 in (152 mm) behind the panel
Specifications
Options Installed |
N/A 4 Relays & 4-20 mA Output |
Power Options |
N/A 12/24 VDC ±10%, 15 W max |
Display |
N/A 0.60 in (15 mm) high red LEDs, 6 digits |
Inputs |
N/A Thermocouples J, K, T, E, R, S, B, N, C and RTD 100 Ohm Platinum (0.00385 & 0.00392 curves), 10 Ohm Copper, 120 Ohm Nickel, 1000 Ohm Platinum |
Resolution |
N/A 1º (up to 4 Digits) or 0.1º (up to 5 Digits) |
Temperature Limit |
N/A -20 to 65 ºC |
Width |
N/A 4.680 in119.00 mm |
Height |
N/A 2.450 in62.00 mm |
Depth |
N/A 5.640 in143.00 mm |
General Specifications
N/A
Except where noted all specifications apply to operation at +25 ºC. |
Temperature Inputs
N/A
|