• Averages up to 10 RTD Sensors
  • Automatic Cold Junction Compensation
  • NEMA 4X, IP65 Front
  • Universal 85-265 VAC or 12/24 VDC Input Power
  • Large Dual-Line 6-Character Display, 0.60" & 0.46"
  • Programmable Displays & Function Keys
  • Sunlight Readable Display
  • 2 or 4 Relays + Isolated 4-20 mA Output Options
  • External 4-Relay & Digital I/O Expansion Modules
  • RS-232, RS-422/485 Serial Communication Options
  • Modbus® RTU Protocol Standard
Notes:
1. Panel cutout required: 1.772 in x 3.622 in (45mm x 92mm)
2. Panel thickness: 0.040 - 0.250 in (1.0mm - 6.4mm)
3. Mounting brackets lock in place for easy mounting
4. Clearance: Allow 6 in (152 mm) behind the panel
Unit of Measure

Specifications

Options Installed

N/A 4-20 mA Output

Power Options

N/A 12/24 VDC ±10%, 15 W max

Display

N/A 0.60 in (15 mm) high red LEDs, 6 digits

Inputs

N/A Thermocouples J, K, T, E, R, S, B, N, C and RTD 100 Ohm Platinum (0.00385 & 0.00392 curves), 10 Ohm Copper, 120 Ohm Nickel, 1000 Ohm Platinum

Resolution

N/A 1º (up to 4 Digits) or 0.1º (up to 5 Digits)

Temperature Limit

N/A -20 to 65 ºC

Width

N/A 4.680 in119.00 mm

Height

N/A 2.450 in62.00 mm

Depth

N/A 5.640 in143.00 mm

General Specifications

N/A Except where noted all specifications apply to operation at +25 ºC.

  • Display: Main display: 0.60" (15 mm) high red LEDs; second display: 0.46" (12 mm) high red LEDs. Both displays have six-characters with leading zero blanking. Temperature value is four or five-digit F/C, based on configuration.
  • Display Intensity: Eight intensity levels
  • Display Update Rate: 5/second (200 ms)
  • Front Panel: NEMA 4X, IP65
  • Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro S/W, Modbus registers, or cloning using Copy function.
  • Noise filter: Programmable from 2 to 199 (0 will disable filter)
  • Filter Bypass: Programmable from 0.1 to 99.9% of span
  • Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months.
  • Max/Min Display: Max / min temperature readings are stored until reset by the user or until power to the meter is turned off.
  • Password: Three programmable passwords restrict modification of programmed settings. Pass 1: Allows use of the F1-F3 function keys. Pass 2: Allows use of the F1-F3 function keys and changing the set/reset points. Pass 3: Restricts all programming and F1-F3 keys.
  • Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
  • Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
  • Normal Mode Rejection: Greater than 65 dB at 50/60 Hz
  • Isolation: 4 kV input/output-to-power line. 500 V input-to-output
  • Environmental: Operating temperature range: -20 to 65 ºC. Storage temperature range: -40 to 85 ºC. Relative humidity: 0 to 90% non-condensing.
  • Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
  • Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
  • Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
  • Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
  • Weight: 9.5 oz (269 g)
  • UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment.
  • Warranty: 3 years parts & labor

Temperature Inputs

N/A

  • Input Impedance: Greater than 100 kOhm
  • Offset Adjust: User programmable offset adjust ± 199.9 degrees
  • Temperature Drift: ± 2 ºC maximum from 0 to 65 ºC ambient temperature; ± 4 ºC maximum from -20 to 0 ºC ambient temperature
  • Sensor Break: Display flashes "Open", relays can be programmed to go "On", "Off", or to "Ignore" (detected as an upscale condition).
  • Averaging: Up to 10 RTDs connected in parallel can be averaged.