• J, K, T, E Thermocouple & 100 Ohm Pt RTD
  • Pre-Calibrated for All Input Types
  • NEMA 4X, IP65 Front
  • Shallow Depth 1/8 DIN Case 3.2" Behind Panel
  • 4 Digit Display, 0.56" (14 mm) High, Red LEDs
  • Easy Front Panel Programming
  • Maximum/Minimum Display
  • Universal Power Supply 85-265 VAC
  • 12-36 VDC/12-24 VAC Power Option
Unit of Measure

Specifications

Power Options

N/A 85-265 VAC, 50/60 Hz; 90-265 VDC, 8 W max

Display

N/A 0.56 in (14.2 mm) red LED, 4 digits (-1999 to 9999)

Inputs

N/A Thermocouples J, K, T, E and RTD 100 Ohm Platinum (0.00385 or 0.00392 Curve)

Resolution

N/A 1º; type T: 1º or 0.1º

Temperature Limit

N/A 0 to 65 ºC

Width

N/A 4.680 in116.00 mm

Height

N/A 3.790 in96.00 mm

Depth

N/A 2.450 in62.00 mm

General Specifications

N/A Except where noted all specifications apply to operation at +25 ºC.

  • Front Panel: NEMA 4X, IP65; panel gasket provided
  • Programming Methods: Four front panel buttons
  • Display Update Rate: RTD: 5/sec; TC: 2.5/sec
  • Overrange: Display flashes - 9999
  • Underrange: Display flashes -1999
  • Recalibration: All inputs are calibrated at the factory; recalibration is recommended at least every 12 months.
  • Max/Min Display: Stored until reset by user or meter is turned off.
  • Password: Restricts modification of programmed settings.
  • Non-Volatile Memory: Settings stored for a minimum of 10 years.
  • Required Fuse: UL Recognized, 5 A max, slow-blow; up to 6 meters may share one fuse.
  • Normal Mode Rejection: 64 dB at 50/60 Hz
  • Isolation: 4 kV input/output-to-power line
  • Storage Temperature: -40 to 85 ºC
  • Relative Humidity: 0 to 90% non-condensing
  • Connections: Power & Signal: removable screw terminal blocks accept 12 to 22 AWG. Note: RJ11 header for factory use only.
  • Enclosure: 1/8 DIN, high impact plastic, 94 V-0, color; gray
  • Weight: 8.5 oz (241 g)
  • UL File Number: E160849; 508 Industrial Control Equipment
  • Warranty: 1 year parts & labor
  • Extended Warranty: 1 or 2 years, refer to Price List for details.

Temperature Inputs

N/A

  • Cold Junction Reference: Automatic
  • Temperature Drift: ± 2 ºC Maximum
  • Input Impedance: Greater than 100 kOhm